Found by reading the unencrypted VM disk after run #7: 1. Online branding never ran: Apply-Branding.ps1 had a UTF-8 em-dash in a Write-Warning STRING; Windows PowerShell 5.1 (SetupComplete) reads .ps1 as ANSI, mangled it, broke the string terminator -> whole script failed to parse -> lock/login/wallpaper branding never re-applied. Fix: ASCII-ify the em-dash AND save the branding scripts UTF-8-with-BOM so PS5.1 always decodes them correctly (verified parses under PS5.1 + PS7). 2. sm-bootstrap never removed: TearDownAsync used schtasks /tr with an inline -EncodedCommand, which silently fails past the ~261-char /tr limit, so the cleanup task was never created (confirmed NO_TASK on disk). Fix: Register-ScheduledTask (no length limit). 3. Done step: show a QR code of the BitLocker recovery key (QRCoder) for phone backup, and lay key+QR side-by-side so the Restart button no longer overflows below the fold. Verified: welcome solution builds, 29/29 tests; branding Pester 6/6 unit (offline-integration needs elevation, runs in CI). Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SilverMetal Windows branding (shared, dual-mode)
Apply-Branding.ps1 writes the four branding layers either OFFLINE into a
mounted WIM (-Mode Offline -MountPath <mount>, used by installer/build.ps1
Invoke-Brand) or ONLINE onto the running system (-Mode Online, self-apply).
Strings live in branding.manifest.json; images in assets/. See
docs/superpowers/specs/2026-06-09-first-boot-branding-design.md.
Layers: BitLocker pre-boot recovery message, lock-screen image (locked), desktop wallpaper+theme (changeable), OEM About.