fix(windows): hardening modules never ran (SetupComplete quoting bug)
VM runtime test (offline disk mount) revealed SetupComplete.cmd ran but its inline
multi-line `powershell -Command` (cmd ^-continuation + nested escaped quotes) failed
to parse ("string is missing the terminator") -> the §A-H modules never executed.
Offline CI assertions only proved the files were BAKED, not that they RUN.

Fix: move the module runner into hardening/Invoke-Hardening.ps1 and call it with
-File (no cmd quoting). Runner runs 00*..08* in order then Verify (writes
verify-report.json in-line as SYSTEM; reboot/PIN-dependent gates show pending).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>